Automatic Boiler Water Softener
Single Valve Single Tank
Industrial full-automatic water softening system using high-quality ion exchange resin to remove calcium and magnesium ions, preventing scale buildup and extending boiler service life.
23+ premium boiler auxiliary products across 4 categories, serving industrial clients worldwide.
Industrial water softening and treatment systems for optimal boiler feedwater quality.
Single Valve Single Tank
Industrial full-automatic water softening system using high-quality ion exchange resin to remove calcium and magnesium ions, preventing scale buildup and extending boiler service life.
Dual Valve Twin Tank
Heavy-duty twin-tank water softening system with dual-tank alternating regeneration design ensuring continuous, uninterrupted softened water supply for medium-to-large industrial boiler rooms.
Skid-mounted chemical dosing system for precise injection of corrosion inhibitors, scale preventers, and oxygen scavengers. Features reliable metering pumps and steel frame skid for easy installation.
Precision-engineered valves for steam, water, and gas applications in demanding boiler environments.
Spring-loaded
Spring-loaded safety valve for automatic pressure relief in boiler systems. Fast-opening pop action prevents dangerous overpressure. Compliant with ASME VIII and ISO 4126 standards.
Flanged Gate Valve
Cast iron flanged stop valve for reliable pipeline isolation in steam and boiler systems. Bolted bonnet design provides secure sealing and easy maintenance. PTFE gland packing minimizes stem leakage.
Industrial plunger valve for reliable on/off and throttling service in steam, water, and oil systems. Solid push-down plunger stem creates a positive, drip-tight seal without erosion problems common in globe valve designs.
Swing Type
Swing-type cast iron check valve allowing medium to flow in one direction only and automatically closes to prevent backflow when the system is shut down. Low resistance with minimal pressure drop.
Actuator + Globe Valve
Electrically actuated control valve with proportional globe valve body. Accepts 4–20 mA or Modbus signals for precise remote automated flow regulation in boiler and HVAC systems.
OEM-compatible combustion components for reliable industrial burner performance.
Electric servo motor functioning as an air damper actuator for precisely controlling combustion air supply. Receives control signals from burner controller to optimize air-to-fuel ratio across different firing rates.
High-voltage ignition electrode assembly for producing stable spark ignition in gas and light oil burners. Ceramic insulator body and high-temperature-resistant tip withstand repeated sparking cycles and hot combustion gases.
UV Sensor Type
Ultraviolet flame detector monitoring the presence and intensity of flame in gas or oil-fired burners. UV sensor detects unique spectral emission of combustion flames and sends signal to burner controller for safety cut-off.
Microprocessor-based burner controller managing the complete combustion sequence: pre-purge, ignition, flame monitoring, firing rate modulation, and post-purge shutdown. LED status display for easy fault troubleshooting.
Perforated disc flame stabilizer installed at burner nozzle to improve flame anchoring and combustion stability, especially when burning heavy oils or low-quality fuels. Effectively prevents flame lift-off and flashback.
Fuel Oil Transfer
Positive displacement internal gear pump for light fuel oil (No. 0–2) transfer and atomization supply in industrial burners. Precision-machined cast iron housing generates consistent oil pressure for reliable burner atomization.
Measurement, control, and automation components for safe and efficient boiler operation.
Type K
Industrial Type K thermocouple with metal sheath for direct high-temperature measurement up to 1300°C in furnaces, kilns, and boilers. Nickel-chromium/nickel-alumel junction provides accurate readings across wide temperature range.
4–20 mA Output
Industrial pressure transmitter converting boiler and pipeline pressure into standardized 4–20 mA analog signal for PLC, DCS, or SCADA systems. Two-wire current loop design enables reliable long-distance signal transmission.
Bourdon Tube
Bourdon tube-type pressure gauge with dial display for local pressure indication of boiler and pipeline systems. Circular dial with clearly marked scale divisions provides instant, easy-to-read pressure readings at point of measurement.
Industrial bimetal temperature sensor with adjustable-angle dial display for measuring temperature in pipelines, tanks, and process equipment. Self-powered bimetal coil element provides stable and accurate readings without external power.
PT100 / RTD
PT100 platinum resistance temperature sensor providing accurate and stable temperature measurement through change in electrical resistance. Three-wire configuration eliminates lead wire resistance errors for precise reading over long distances.
Differential pressure flowmeter using orifice plate between pipeline flanges to generate measurable pressure drop proportional to square root of flow rate. Suitable for steam, water, and gases in large-diameter pipelines.
Digital Display
Digital vortex shedding flowmeter with LCD display for measuring volumetric flow rate of liquids, gases, and steam. Bluff-body principle generates alternating vortices with frequency directly proportional to flow velocity.
Reflex or transparent glass plate liquid level gauge for direct visual indication of liquid level in boilers, tanks, and pressure vessels. High-pressure gaskets provide safe and reliable visual reference at high pressure.
Transmission/Reflection
Bi-colour liquid level indicator displaying water level with distinct red (water) and green (steam) colour bands. Optical principle provides clear, unambiguous level reading from distance, reducing eye strain for operators.